LATEST NEWS

DataBank Establishes $725M Financing Facility to Support Growth. Read the press release.

Get a Quote

Request a Quote

Tell us about your infrastructure requirements and how to reach you, and one of team members will be in touch shortly.

Schedule a Tour

Tour Our Facilities

Let us know which data center you'd like to visit and how to reach you, and one of team members will be in touch shortly.

Get a Quote

Request a Quote

Tell us about your infrastructure requirements and how to reach you, and one of team members will be in touch shortly.

Schedule a Tour

Tour Our Facilities

Let us know which data center you'd like to visit and how to reach you, and one of team members will be in touch shortly.

Get a Quote

Request a Quote

Tell us about your infrastructure requirements and how to reach you, and one of team members will be in touch shortly.

Schedule a Tour

Tour Our Facilities

Let us know which data center you'd like to visit and how to reach you, and one of team members will be in touch shortly.

Maximizing Data Center Efficiency: Understanding And Improving Power Usage Effectiveness (PUE)
  • DataBank
  • Resources
  • Blog
  • Maximizing Data Center Efficiency: Understanding And Improving Power Usage Effectiveness (PUE)

Maximizing Data Center Efficiency: Understanding And Improving Power Usage Effectiveness (PUE)


Data centers are facilities used to house IT equipment and infrastructure (often in significant quantities). This means that they use a lot of electricity. Understanding and improving their power usage effectiveness (PUE) is, therefore, key to their operations. Here is a quick guide to what you need to know.

Understanding power usage effectiveness (PUE)

Power Usage Effectiveness (PUE) is a metric used to measure the energy efficiency of a data center. It’s calculated by dividing the total energy consumed by the data center facility (including cooling, lighting, and other non-computing loads) by the energy consumed by the IT equipment (servers, storage, networking) within that facility.

Formula: PUE = Total Facility Energy / IT Equipment Energy

A PUE of 1.0 indicates that all the energy consumed by the data center is used exclusively for computing purposes, making it highly efficient. However, in practice, most data centers have PUE values higher than 1.0 due to energy losses from cooling systems, power distribution, and other non-computing functions.

Importance of PUE in data centers

For some data operators, lowering PUE will be necessary to meet energy-efficiency targets laid down by regulatory bodies (including governments. Even when it isn’t, there are many benefits to making a continuous effort to improve PUE. Here are just five of them.

Cost savings: Lowering PUE means less energy is required to support non-computing functions like cooling and lighting, resulting in decreased overall energy consumption for the data center. With reduced energy consumption comes lower electricity bills, leading to significant cost savings for data center operators over time.

Improved environmental sustainability: Lower PUE translates to a smaller carbon footprint and reduced greenhouse gas emissions, contributing to environmental sustainability goals.

Improved equipment reliability: Lower PUE often correlates with more efficient cooling systems, which can help maintain optimal operating temperatures for IT equipment, leading to improved reliability and lifespan of hardware.

Scalability and capacity optimization: By optimizing energy usage and cooling efficiency, data centers can better accommodate increasing workloads and scale their operations without needing proportionally larger infrastructure, maximizing resource utilization and capacity.

Enhanced reputation: Achieving a lower PUE demonstrates a commitment to sustainability and efficiency, which can enhance the reputation of the data center operator and attract environmentally-conscious customers, leading to a competitive advantage in the market.

Strategies for improving PUE in data centers

Here are five strategies data center operators can use to improve their PUE rating.

Optimizing cooling systems

Advanced cooling technologies like liquid cooling and immersion cooling can efficiently remove heat from data center equipment. Liquid cooling involves circulating coolant directly to hot components, such as CPUs and GPUs, while immersion cooling submerges servers in a thermally conductive but electrically insulative liquid.

Both methods are more effective at heat dissipation compared to traditional air cooling, thereby reducing the overall energy needed for cooling.

Implementing free cooling techniques

Free cooling leverages external environmental conditions to reduce the need for mechanical cooling. Air-side economization, for instance, uses outside air to cool the data center when temperatures are suitable. Water-side economization utilizes evaporative cooling towers and chillers to achieve similar effects.

These methods can significantly cut down on the energy required for traditional air conditioning systems, thus improving PUE.

Upgrading IT equipment

Replacing old, inefficient servers and storage devices with modern, energy-efficient models can reduce the power consumption of IT equipment. High-efficiency power supplies, low-power processors, and solid-state drives (SSDs) are examples of technologies that can lower energy use while maintaining or enhancing performance.

Additionally, virtualization can consolidate workloads onto fewer physical machines, further reducing energy requirements.

Enhancing power distribution

Improving the efficiency of power distribution within the data center can also lower PUE. This includes using high-efficiency uninterruptible power supplies (UPS), optimizing power distribution units (PDUs), and ensuring that power conversion and delivery systems minimize losses.

Implementing DC power distribution, which reduces the number of power conversions needed, can also lead to significant energy savings.

Implementing continuous monitoring and management

Deploying advanced monitoring tools to track energy usage in real time can identify inefficiencies and areas for improvement. Data center infrastructure management (DCIM) software can provide insights into power usage patterns and environmental conditions, enabling proactive adjustments.

Incorporating AI and machine learning can further enhance these systems by predicting potential issues and optimizing energy use dynamically, ensuring the data center operates at peak efficiency.

Challenges and solutions

Here is an overview of the three main challenges of lowering PUE and how to solve them.

High initial investment: Adopt a phased approach to investments, starting with the most impactful improvements. Utilize financing options or government incentives for energy efficiency projects to offset initial costs.

Complex infrastructure changes: Conduct thorough planning and incremental upgrades to minimize downtime. Use modular solutions that can be integrated seamlessly with existing infrastructure.

Operational complexity: Integrate centralized management systems that provide a unified view of energy consumption and cooling efficiency. Use AI-driven analytics to simplify decision-making and automate routine tasks, ensuring smooth and efficient operations.

Share Article



Categories

Related Resources

Data Center Energy Efficiency
Blog Article
Green Data Centers: Achieving Data Center Energy Efficiency In Your Colocation Facility

Explore the rise of green data centers. Find out how to achieve data center energy efficiency in your colocation facility. Learn about the role of renewable energy in making data centers more sustainable. Gain insight into how to overcome barriers to improving data center energy efficiency.

iMasons Climate Accord Logo
Press Release
DataBank Joins Infrastructure Masons Climate Accord to Accelerate Carbon Neutrality

Global Initiative Unites Digital Infrastructure Leaders in Historic Climate Agreement

Discover the DataBank Difference

Discover the DataBank Difference

Explore the eight critical factors that define our Data Center Evolved approach and set us apart from other providers.
Download Now
Get Started

Get Started

Discover the DataBank Difference today: